CVEFinder.io

CVE-2026-94142

⚠️ high
🔍 Scan for this CVE
Summary

A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

CVSS Score
8.8
High
EPSS Score
0.1
Exploit Probability
Published Date
2026-09-21
First Seen: 2026-09-24
📊 Relative Risk Intelligence

This CVE is High Risk - more severe than 80.8% of all 361,609 vulnerabilities in our database.

#69,457
Top 25% most severe
Severity Percentile
🎯 CISA SSVC Assessment Updated: Sep 21, 2026
🔍 Exploitation Status
Poc
Proof-of-concept available
⚙️ Automatable
NO
Requires human interaction
💥 Technical Impact
Total
Complete system compromise possible
🏆 Discovered By
Bigcat (VulDB User) (reporter) VulDB CNA Team (coordinator)
SSVC data provided by CISA
Last Modified 2026-09-21
Source NVD 🔗
CVSS Vector 3.1 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
CVSS Vector 4.0 CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CWE IDs (Weakness Types)

📦 Affected Products 0

No affected products information available

🔗 References 4